Roads / Drainage

Subsoil drains and outlets

Estimate in m of drain.

Trench box and pipe-laying front
  1. Shield panelsConfirm the installed protection matches the released trench stage.
  2. Cross strutsAllow for clearances when lowering and joining the pipe.
  3. Pipe beddingInspect levels and support before backfill.
Construction context for Subsoil drains and outlets

Construction method and plant

Locate outlets, cut the trench, install the specified drainage assembly and tie into the outlet. Survey and inspect before cover.

Plant and crew

Trencher or compact excavator, aggregate delivery, geotextile and pipe crew. Confirm outlet access.

Measure and release the lot

Quantity take-off

Measure installed drain length. Take filter aggregate by trench section and outlets by count.

Handover record

Release the covered drainage line with outlet location and photographs to the formation crew.

Short runs, service crossings and inaccessible outlets can dominate the metres installed per shift.

Where this package fits

Productivity references

Use a contractor programme, trial or shift record for this package. Record the quantity accepted, crew configuration, productive hours and delays.

Use the contract edition, annexures and inspection plan for measurement and acceptance on a project.

Survey conformance and lot release

Observe
Check drain invert, grade and outlet location before filter material conceals the pipe.
Compare
Identify the lot and asset, issued drawing revision, coordinate and height datum, control mark and observation method. Compare design and as-built values on a common basis using the specified sampling rule, permissible deviation and measurement uncertainty.
Verify and hand over
Release the covered drainage line with outlet location and photographs to the formation crew.
Resolve exceptions
Map the affected extent, retain the original observation and record the authorised disposition. Recheck corrected work against the same criterion and link the result to the original lot before release.
The software behind Vaultix

Measure it in Spark. Price it in Trinity.

Take quantities off the PDF drawings in Spark, then build the rate from labour, plant, materials and productivity in Trinity.